Holter recorder provides one day of continuous ECG data. It has a 10-lead wire patient cable providing 24 hour 12- Lead ECG data. It samples at a rate of 4096 samples per second.
The V Bravo Company,
Applied Cardiac Systems, Inc,
Medical Equipment Dynamics, Inc.,
more...
AZReam, Inc.,
Nihon Kohden America, Inc.,
Wholesale Point, Inc.,
more...
(FDA Code:
JOM /
870.278)
Identification. A hydraulic, pneumatic, or photoelectric plethysmograph is a device used to estimate blood flow in a region of the body using hydraulic, pneumatic, or photoelectric measurement techniques.
Classification. Class II (performance standards).
ACI Medical, LLC.,
Elmed Inc.,
Vyaire Medical, Inc.,
more...
Adroit Medical Systems
(FDA Code:
NZE /
870.59)
Identification. A thermal regulating system is an external system consisting of a device that is placed in contact with the patient and a temperature controller for the device. The system is used to regulate patient temperature.
Classification. Class II (performance standards).
Life Recovery Systems Hd, Llc.,
Rand S.R.L.
Zimmer, Inc.,
Rankin Biomedical
Raytel Medical Corporation
(FDA Code:
NIO)
Medtronic Xomed Surgical Products, Inc,
Cordis Corp.,
Ev3, Inc.,
more...
Philips Medical Systems,
Scimage, Inc.,
Eastman Kodak Company,
more...
Philips Medical Systems,
Scimage, Inc.,
Eastman Kodak Company,
more...
Philips Medical Systems,
Scimage, Inc.,
Eastman Kodak Company,
more...
Philips Medical Systems,
Scimage, Inc.,
Eastman Kodak Company,
more...
Philips Medical Systems,
Scimage, Inc.,
Eastman Kodak Company,
more...
Eastman Kodak Company,
MedPACS Display, Inc.
Philips Medical Systems,
Scimage, Inc.,
Eastman Kodak Company,
more...
Bracco Diagnostics Inc.,
Erie Scientific
Bracco Diagnostics Inc.
Bracco Diagnostics Inc.,
Erie Scientific
Elmed Inc.,
Dermed Diagnostics, Inc.,
Medis Medizinische Messtechnik Gmbh
Impedance cardiography system is used for real-time noninvasive cardiac output measurement. It also provides measures of cardiac flow, rather than pressure measurements. This system uses sensors to detect the properties of the blood flow in the thorax.
CardioDynamics,
Elmed Inc.,
Instrumentation For Medicine, Inc.,
more...
(FDA Code:
DSB /
870.277)
Identification. An impedance plethysmograph is a device used to estimate peripheral blood flow by measuring electrical impedance changes in a region of the body such as the arms and legs.
Classification. Class II (performance standards).
CardioDynamics,
ACI Medical, LLC.,
Elmed Inc.,
more...
(FDA Code:
NQH /
870.2855)
Cardiomems, Inc.,
Sparton Medical Systems
Implantable cardiac defibrillator is a device, which is put within the body. It is to recognize certain types of abnormal heart rhythms (arrhythmias) and correct them. It continuously monitors the heart rhythm in order to detect overly rapid arrhythmias such as ventricular tachycardia and ventricular fibrillation. These ventricular arrhythmias impair the pumping efficiency of the heart and greatly raise the risks of fainting and sudden cardiac arrest. It corrects the heart rhythm by delivering precisely calibrated and timed electrical shocks, when needed, to restore a normal heartbeat.
Ventritex, Inc.,
Medtronic Ophthalmics,
Cardiac Science, Inc.,
more...
(FDA Code:
MXC /
870.28)
Identification. A medical magnetic tape recorder is a device used to record and play back signals from, for example, physiological amplifiers, signal conditioners, or computers.
Classification. Class II (performance standards).
Medtronic Xomed Surgical Products, Inc,
St. Jude Medical, Inc.,
Medtronic Ablation Frontiers LLC,
more...
An implantable cardioverter defibrillator is a device like pacemaker. It is placed under the skin just below the collarbone. The device uses leads to monitor every single heartbeat. If a lethal rhythm appears, the defibrillator shocks the heart back to a normal rhythm. It monitors the patient's heart rhythm, and automatically administers shocks for various life threatening arrhythmias, according to the device's programming. It is used in patients at risk for recurrent, sustained ventricular tachycardia or fibrillation. The device is connected to leads positioned inside the heart or on its surface. These leads are used to deliver electrical shocks, sense the cardiac rhythm and sometimes pace the heart, as needed. The various leads are tunneled to a pulse generator, which is implanted in a pouch beneath the skin of the chest or abdomen. These generators are typically a little larger than a wallet and have electronics that automatically monitor and treat heart rhythms recognized as abnormal.
Medtronic, Inc.,
Medtronic Ophthalmics,
St. Jude Medical, Inc.,
more...
Medtronic Ophthalmics
An implantable defibrillator is a device, which is used to monitor heart rate. It uses batteries to send electric signals to a heart that's beating too slow, similar to a pacemaker. It can also deliver an electric shock to help restore a normal heartbeat to a heart that's beating chaotically and much too fast. Cardiac defibrillation is a way to return an abnormally fast or disorganized heartbeat to normal with an electric shock. The device is inserted under the skin in the chest or abdomen. The procedure is similar to that of a pacemaker insertion. One wire is connected to the heart and another is connected to the defibrillator unit. The defibrillator unit monitors the heart rhythm, sends an electrical shock and keeps a record of the events. If the heart is beating normally, the ICD is inactive. When an abnormal, fast heart rate, known as a tachycardia, is detected, the ICD will send electric shock signals to the heart. The electric shock converts the abnormal rhythm to a normal rhythm. The low energy electric shocks delivered by the ICD do not harm the patient or anyone in physical contact with the patient. The patient may feel the symptoms of the tachycardia as it begins.
Ventritex, Inc.,
Heartland Medical Sales and Services LLC,
Medtronic Ophthalmics,
more...
Enpath Medical, Inc.,
St. Jude Medical, Inc.,
Boston Scientific Corporation,
more...
The implantable loop recorder is a small device implanted subcutaneously close to the heart. It has the ability to record the electrical activity of the heart, store rhythm disturbances within set parameters and can be triggered by the patient to store events. The loop recorder is a device with a high diagnostic yield and offers precision in diagnosis to the enlightened specialist.
Medtronic Ophthalmics
Medtronic, Inc.
Medtronic, Inc.
Medtronic Ophthalmics,
Ccc Medical Devices
(FDA Code:
NKE)
St. Jude Medical, Inc.,
Guidant Puerto Rico B.V.,
Biotronik, Inc.,
more...
(FDA Code:
NVZ)
Medtronic Xomed Surgical Products, Inc,
St. Jude Medical, Inc.,
Impulse Dynamics USA Inc.,
more...
Thoratec Corporation,
Abbott Vascular Devices,
Autosuture,
more...
Medtronic, Inc.
Medtronic Ophthalmics
Incentive Spirometer is used to examine the health of the lungs by measuring inspiratory volume. An incentive spirometer is used by people who need to exercise their lungs. This spirometer measures two important numbers such as FEV1 (air flow) and FEV6 forced vital capacity (air volume). These incentive spirometers help simplify deep breathing therapy, using features that prompt patients to perform and monitor their own postsurgical breathing exercises.
Creative Biomedics, Inc.,
Tri-anim Health Services, Inc.,
Vacumed,
more...
Hospira, Inc.,
B. Braun Medical Inc.,
Mennen Medical Corp.,
more...
(FDA Code:
DXL /
870.166)
Identification. An indicator injector is an electrically or gas-powered device designed to inject accurately an indicator solution into the blood stream. This device may be used in conjuction with a densitometer or thermodilution device to determine cardiac output.
Classification. Class II (performance standards).
Advanced Biomedical Devices, Inc. (ABD, Inc.)
Rushed Box,
A&D Medical,
CSA Medical Supply,
more...
(FDA Code:
KRE /
870.364)
Identification. An indirect pacemaker generator function analyzer is an electrically powered device that is used to determine pacemaker function or pacemaker battery function by periodically monitoring an implanted pacemaker's pulse rate and pulse width. The device is noninvasive, and it detects pacemaker pulse rate and width via external electrodes in contact with the patient's skin.
Classification. Class II (performance standards).
Medtronic Xomed Surgical Products, Inc,
Cardionet, Inc.,
Benchmark Electronics (Thailand) Public Company Ltd
A&D Medical,
KCK Medical,
Schueler & Company Inc,
more...
Infant stethoscopes are designed for little patients. Stainless steel chest pieces are optimally sized for infant auscultation. It has a 3/4-inch bell for an easier chest wall seal. These precision instruments are also designed to maximize the comfort of both patient and professional. The solid stainless steel chest pieces on the infant stethoscopes are optimally sized for little patients. The small diaphragm conforms to the contours of infant bodies.
Scrub Cabana,
Medical Warehouse,
Medisave USA LLP,
more...
Infant, Double-head stethoscope provides accurate auscultation of heart, lung and blood pressure sounds as well as overall durability and aesthetics. It is only recommended for infants.
Dealmed Medical Supplies,
Welch Allyn, Inc.,
Kentron Health Care, Inc.
Vitae Core,
Navilyst Medical, Inc.,
Merit Medical Systems, Inc.,
more...
Cardionics, Inc.,
Philips Medical Systems, N.A.,
3J Tech Co., Ltd.
Kaisers Surgical Instruments Pty Ltd
Fresenius SE,
Boehringer Ingelheim GmbH,
Sedat
Cardima, Inc.