Profile: Fisher Scientific International, Inc. provides products & services to the scientific research community & clinical laboratories. We manufacture and distribute a wide array of diagnostic kits & reagents, equipment, instruments & other consumable products to hospitals & group-purchasing organizations, clinical laboratories, reference laboratories, physicians' offices as original equipment. We also offer outsourced manufacturing services for diagnostic reagents, calibrators & controls to the healthcare and pharmaceutical industries.
The company has revenues of USD 50-100 Million, has ~3300 employees. NYSE:FSH (SEC Filings)
FDA Registration Number: 2431530
• 12 Hole Test Tube Rack |
• 3-Tiler Test Tube Stand |
• 5'-Nucleotidase 5-AMP-Phosphate Release (Colorimetric Test) (FDA Code: CED / 862.1520) A 5'-nucleotidase test system is a device intended to measure the activity of the enzyme 5'-nucleotidase in serum and plasma. Measurements of 5'-nucleotidase are used in the diagnosis and treatment of liver diseases and in the differentiations between liver and bone diseases in the presence of elevated serum alkaline phosphatase activity. |
• AC-Powered Transilluminator (FDA Code: HJM / 886.1945) A transilluminator is an AC-powered or battery-powered device that is a light source intended to transmit light through tissues to aid examination of patients. |
• Acetone |
• Acid Containing Decalcifier Pathology Solution (FDA Code: KDX / 864.4010) |
• Acid Fuchsin Stain (FDA Code: IDF / 864.1850) Dye and chemical solution stains for medical purposes are mixtures of synthetic or natural dyes or nondye chemicals in solutions used in staining cells and tissues for diagnostic histopathology, cytopathology, or hematology. |
• Acid, Hydroxyazobenzene-Benzoic, Albumin (FDA Code: CJZ / 862.1035) An albumin test system is a device intended to measure the albumin concentration in serum and plasma. Albumin measurements are used in the diagnosis and treatment of numerous diseases involving primarily the liver or kidneys. |
• Acridine Orange Stain (FDA Code: IDC / 864.1850) |
• Adhesive Bandage Strip |
• Adhesive Bandages (FDA Code: KGX / 880.5240) A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists of a strip of fabric material or plastic, coated on one side with an adhesive, and may include a pad of surgical dressing without a disinfectant. The device is used to cover and protect wounds, to hold together the skin edges of a wound, to support an injured part of the body, or to secure objects to the skin. |
• Adult Tongue Depressor (FDA Code: FMA / 880.6230) A tongue depressor is a device intended to displace the tongue to facilitate examination of the surrounding organs and tissues. |
• Aerobic Incubator |
• Alcian Blue Stain (FDA Code: IDA / 864.1850) |
• Alizarin Red Stain (FDA Code: IDD / 864.1850) |
• Alkaline Phosphatase Isoenzymes Electrophoretic Separation Test (FDA Code: CIN / 862.1050) An alkaline phosphatase or isoenzymes test system is a device intended to measure alkaline phosphatase or its isoenzymes (a group of enzymes with similar biological activity) in serum or plasma. Measurements of alkaline phosphatase or its isoenzymes are used in the diagnosis and treatment of liver, bone, parathyroid, and intestinal diseases. |
• Ampule |
• Ampule Opener |
• Amylase Catalytic Method Test (FDA Code: JFJ / 862.1070) An amylase test system is a device intended to measure the activity of the enzyme amylase in serum and urine. Amylase measurements are used primarily for the diagnosis and treatment of pancreatitis (inflammation of the pancreas). |
• Anaerobic Incubator |
• Analytical Laboratory Instrument |
• Anatomical Training Model |
• Angled Tongue Depressor |
• Animal Cage |
• Antibacterial Cleaner Solution |
• Antibiotic Sensitivity Disc Dispenser |
• Antisera, Control for Non-Treponemal Test (FDA Code: GMP / 866.3820) |
• Atraumatic Hemostatic Forceps |
• Autoclave Accessories, Immersion Heater |
• Automated Hemoglobin System (FDA Code: GKR / 864.5620) An automated hemoglobin system is a fully automated or semi-automated device which may or may not be part of a larger system. The generic type of device consists of the reagents, calibrators, controls, and instrumentation used to determine the hemoglobin content of human blood. |
• Automated Slide Staining Machine |
• Automated Tissue Processor (FDA Code: IEO / 864.3875) An automated tissue processor is an automated system used to process tissue specimens for examination through fixation, dehydration, and infiltration. |
• Automatic Blood Tubing Clamp (FDA Code: FIG / 876.5820) A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer. |
• Automatic Rotary Microtome (FDA Code: IDO / 864.3010) Tissue processing equipment consists of devices used to prepare human tissue specimens for diagnostic histological examination by processing specimens through the various stages of decalcifying, infiltrating, sectioning, and mounting on microscope slides. |
• Azure A Stain (FDA Code: ICQ / 864.1850) |
• Bacteria Counter |
• Bandage/Gauze/Plaster Scissors (Cutter, Shears) |
• Biebrich Scarlet Stain (FDA Code: ICN / 864.1850) |
• Bilirubin and Conjugates Colorimetric Azo-Dyes Test (FDA Code: JJB / 862.1115) A urinary bilirubin and its conjugates (nonquantitative) test system is a device intended to measure the levels of bilirubin conjugates in urine. Measurements of urinary bilirubin and its conjugates (nonquantitative) are used in the diagnosis and treatment of certain liver diseases. |
• Bilirubin Diazo Colorimetry Test (FDA Code: CIG / 862.1110) A bilirubin (total or direct) test system is a device intended to measure the levels of bilirubin (total or direct) in plasma or serum. Measurements of the levels of bilirubin, an organic compound formed during the normal and abnormal distruction of red blood cells, if used in the diagnosis and treatment of liver, hemolytic hematological, and metabolic disorders, including hepatitis and gall bladder block. |
• Biological Refrigerator |
• Black Stopper Blood Collection Tube |
• Blender/Mixer (FDA Code: JRO / 862.2050) General purpose laboratory equipment labeled or promoted for a specific medical use is a device that is intended to prepare or examine specimens from the human body and that is labeled or promoted for a specific medical use. |
• Blood Bank Refrigerator |
• Blood Cell Diluent (FDA Code: GIF / 864.8200) A blood cell diluent is a device used to dilute blood for further testing, such as blood cell counting. |
• Blood Collection Needles |
• Blood Collection Sets with Needle Holder |
• Blood Collection Tube |
• Blood Collection Tube Holder |
• Blood Culturing System (FDA Code: MDB / 866.2560) A microbial growth monitor is a device intended for medical purposes that measures the concentration of bacteria suspended in a liquid medium by measuring changes in light scattering properties, optical density, electrical impedance, or by making direct bacterial counts. The device aids in the diagnosis of disease caused by pathogenic microorganisms. |